EN
Flush Diaphragm Pressure Transmitter XY-PTGP
  • Flush Diaphragm Pressure Transmitter XY-PTGP
  • Flush Diaphragm Pressure Transmitter XY-PTGP
  • Flush Diaphragm Pressure Transmitter XY-PTGP

Flush Diaphragm Pressure Transmitter XY-PTGP

Flush Diaphragm Pressure Measurement; Meets 3-A Sanitary Standards
Excellent Reverse polarity, instantaneous Overcurrent and Overvoltage protection, Applied to High stability and sensitivity for high temperature, high viscosity and the medium are prone to clogging, or Food, Pharmaceuticals and Biotechnology

Typical Feature

  • Clamp flush diaphragm meets 3-A Sanitary Standards 
  • Stainless steel shell can be used in width Measured Medium 
  • Output signals 4~20mA, 0~5VDC,0~10VDC ,1-5VDC
  • Reverse polarity, instantaneous Overcurrent and Overvoltage protection
  • Applied to High stability and sensitivity for high temperature, 
  • high viscosity and the medium are prone to clogging, or Food, 
  • Pharmaceuticals and Biotechnology 
  • Customized structure diversification is available.

Flush Diaphragm Pressure Transmitter XY-PTGP Brief Introduction

XUYAN XY-PTGP Flush Diaphragm Pressure Transmitter, with stainless steel shell and laser-welded construction, is designed to suit 3-A sanitary standards; IP65 Ingress Protection, and Safety Explosion-proof, these performances makes it able to withstand harsh rugged application environments.in addition, this flush diaphragm pressure transducer also has the following advantages: high precision, fast response, small size, light weight, stable and reliable, strong overload capacity.

High stability and sensitivity for high temperature, high viscosity and the medium is prone to clogging, all this performance makes XY-PTGP flush diaphragm pressure transmitter/transducer can be used in food and beverage, pharmaceuticals and biotechnology, chemical glue, mobile working machine and tunneling application, such as air, oil, water and others fluid; Thoughtful specialized electric circuit design; ultra-high precision absolute pressure calibration equipment calibration; Accuracy class 0.25%; 0.5%. 4~20mA, 0~5VDC, 0~10DC standard electrical signal output with remote transmission alternative; Measurement Range: -100KPa~60 MPa., other measurement range is optional. Temperature Stability Index can be increased to 0.02%/FS/ by using sensor temperature self-compensation and specialized circuit debugging.

Flush Diaphragm Pressure Transmitter XY-PTGP Specification

Model XY-PTGP
General Pressure Range -100KPa~0…1…5…10…25...60MPa
Pressure Type Gauge Pressure Test
Dimension Diameter Ф27
Overload Capacity 200-400%
Measurement Medium Gas or Liquid with Compatibility of SS 304 or SS316
Output Single 4~20Ma, 0~5VDC,0~10VDC  
Power Supply 9-32VDC, Typical 24VDC
Insulating Strength >100MΩ at 500VDC excitation
Accuracy 0.25%, 0.5%
Long-Term Stability/Year Typical: ±0.2% FS/Year
Zero Temperature Drift Typical: ±0.02%FS/℃; Maximum ±0.05%FS/℃
Sensitivity Temperature Drift Typical: ±0.02%FS/℃; Maximum ±0.05%FS/℃
Response Time ≤1ms
Mechanical Life ≥5Million Pressure Cycle
Operation Temperature -30~100℃; -40~125℃
Compensation Temperature 0~60℃
Load Resistance ≤[(U-6.6V)/0.02A] Ω
IP Protection Class IP65; IP67; IP68

PDF Download

File Name Online reading File download
Flush Diaphragm Pressure Transmitter XY-PTGP

More details for XY-PTGP, please Contact Us.

Leave us Message
Contact